Recover refrigerant from low-pressure systems (chillers, R-11, R-113).

About this skill

Recovery from low-pressure appliances (centrifugal chillers, R-11, R-113, R-123 systems) using a low-pressure-rated recovery machine that can pull a vacuum.

12 total steps
5 critical steps
Time limit: 20 min

What graders are watching for

  • 1
    Low-pressure recovery requires a vacuum-rated machine
  • 2
    Recovery threshold: 0 psig held for 5 minutes
  • 3
    R-11 and R-113 are CFCs being phased out

Common mistakes (and how to avoid them)

  • !
    Using a high-pressure recovery machine (cannot pull vacuum)
  • !
    Stopping recovery at 0 psig without holding for 5 minutes
  • !
    Failing to identify the refrigerant before recovery